N700E N700 N5000
Home » For pumps and fans

Medium Voltage Inverter N5000

Feauteres

Environment-friendly system to meet harmonic waves rule (IEEE 19-1992) by serialized multiplex drive
High power factorand electric conversion efficiency
High efficient operation by sensorless vector control
Economic installation by slimming
Easy maintenance by modularization
Easy operation by one touch screen digital operator
Remote console on user-friendly windows OS

Specification

Standard Specification

Voltage Class 3300V
3.3kV output
capacity(kVA)
200 300 400 500 600 750 1000 1250 1500 1750 2000 2250 2700 3000 3500 4000
Rated output
current(A)
35 53 70 88 105 132 175 219 263 307 350 394 473 525 619 707
Motor power
output(kW)
155 245 325 410 490 620 835 1040 1270 1500 1710 1940 2250 2500 2800 3200
Voltage Class 4160V
4.16kV output
capacity(kVA)
250 380 500 640 750 950 1250 1550 1900 2200 2500 2850 3400 3750 4400 5000
Rated output
current(A)
35 53 70 89 105 132 174 216 264 306 347 396 472 525 619 707
Motor power
output(kW)
205 310 410 530 630 790 1040 1310 1630 1900 2160 2460 2930 3240 3500 4000
Voltage Class 6600V
6.6kV output
capacity(kVA)
400 600 800 1000 1200 1500 2000 2500 3000 3500 4000 4500 5400 6000 7000 8000
Rated output
current(A)
35 53 70 88 105 132 175 219 263 307 350 394 473 525 619 707
Motor power
output(kW)
330 495 675 835 1000 1270 1700 2130 2590 3020 3450 3930 4500 5000 5600 6400
Input Main circuit 3-phase 3300V,
50/60Hz or 3-phase 6600V, 50/60Hz
Control circuit 3-phase 220V or
440V, 50Hz or 60Hz
Tolerance Voltage : ±10%,
Frequency : ±5%
Output Output frequency(Hz) 50 or 60Hz
Overload ccapacity 120%, 60sec
Power factor
of main power supply
Approx. 95%
or more at normal operating speed
Efficiency Approx. 96%
(including transformer)
N5000 Catalog

N5000 Instruction Manual.PDF